Manual or Automatic valves for filter and Water Softener

We Only sell Wholesale | Same day shipping

Manual or automatic valves for filter and Water Softener Valve

Manual valves for filter and Water Softener are manually operated valves for use on water purification systems. Being resistant, inexpensive and easy to install, they are one of the most used valves in water purification treatment plants. They are also known as manual flow control valves. Applications include: equipment made of zeolite, sand, gravel, garnet, or some and other filter special media, Residential softeners or filters, Iion exchange equipment, Aactivated carbon purifiers, Iindustrial water treatment and pre-treatment systems, Filtration equipment for swimming pools.


Automatic valves are widely used for commercial and residential water filters and softener.

CLACK

Housing img

WS2HF

  • Control Valve Flow Rates: Service 165 gpm (624 lpm) (37 m3/h)
    Backwash 175 gpm (662 lpm) (39 m3/h)
  • Epoxy coated lead free brass valve body
  • Fully programmable regeneration cycle times and sequences (maximum 9)
  • Network up to 16 valves using Cat5 cable or better
  • Methods to initiate regeneration: Meter Delayed, Meter Immediate, Time Clock Delay, Auxiliary Input, Modbus Initiated
  • Add up to 2 relay expansion boards to circuit board (sold separately)
  • Top-mount or side-mount capabilities for commercial and industrial applications
  • Programmable System types: Single, Alternating, Progressive Flow, Series
  • Day override feature; 1-28 days or 7 day
  • Blue backlight front display shows: Time and Date, Current Flow Rate, Volume Used, Volume Remaining, Days Remaining
  • Diagnostics and history viewing
  • Modbus RS485 duplex to communicate with building automation systems
  • On-Site circuit board software update capability
  • Reliable and proven DC drive
  • One piece expanding seal spacer stack assembly
General  
Inlet/Outlet Fitting Connections 2" Female NPT or BSPT
Cycles up to 9
Valve Material Lead free brass
Regeneration Downflow
Operating Pressures 20 - 125 psi (1.4 - 8.6 bar)
Operating Temperatures 40º - 110º F (4º - 43º C)
Options Backwash Filter
FLow rates  
Service @15 psi drop 125 gpm (473 lpm) (28.4 m3 /h)
Backwash @25 psi drop 125 gpm (473 lpm) (28.4 m3 /h)
Cv Service 32.3
Cv Backwash 25.0
Tank applications  
Water Softener 18" - 63" diameter
Water Filter 18" - 48" diameter
Dimensions & Weight  
Distributor Pilot Valve Bodies with 2" Female NPT Inlet & Outlet - 2.375" OD (2" NPS)
Valve Bodies with 2" Female BSPT Inlet & Outlet - 63mm OD
Drain Line 2" Female NPT/BSPT/2.5" Groove Lock
Brine Line 1" Male NPT elbow
¾" x 1" solvent weld elbow
Optional Adapters - 1/2" or 5/8" OD Poly Tube Compression
Mounting Base 4" - 8 UN, 6" Flange or Side Mount
Height From Top Of Tank With 4" - 8 UN QC Base - 11.5" (292mm)
With 6" Flange QC Base - 11.6" (294.6mm)
Weight 50 lbs (22.7 Kg)
Cycles of Operation
Minutes
 
Backwash 1st (upflow) 1 - 95
Regenerate Draw/Slow Rinse (downflow) 1-180 / 1-95
Fast Rinse (downflow) 1-95
Regenerant Refill
in service with treated water
0.1 - 99
Hold (service) 1 - 480
Electrical Specifications
All models excluding WS1.25SD
US Power Supply International Power Supply
Supply Voltage 120VAC 240VAC
Supply Frequency 60 Hz 60 Hz
Output Voltage 24VDC 24VDC
Output Current 800 mA 800 mA

DATA SHEET WS2HF

Housing img

CL D1400 1" IN/OUT HEAD

Housing img

BYPASS ASSEMBLY

Can be used with any brand of filter valve, softener valve, or in/out filter (all kind of adapters are available)
For valves 1” (V3006), 1.25” (V3006), 1.5” (V3097), 2” (V3098), 3” (V3099)
Operating pressure: 20-125 psi
Operating temperature: 40-110 °F (4-43 °C)
For installation on cold water supply only

TWIN CONTROL VALVES

In/Out 1" 1.25" 1.5" 2"
Item Part VTT1EEDM Ask Ask Ask
Configuration 2 valves V1EEDM with V3069 motorized alternator 2 valves V125EEDM with V3069 motorized alternator 2 valves V15EEDT with V3071 motorized alternator and V3040-15 meter 2 valves V2EEDT with V3076 motorized alternator and V3094-15 meter

Housing img

3” CONTROL VALVE (SOFTENER)

  WS3
Type by Meter
Service Flow @ 15psi drop
250 gpm
Backwash Flow @ 25psi drop
220 gpm
Drain connection 3" FNPT
Brine connection 1" NPT
Distributor pipe 90 mm OD
Meter flow 13-1325 lpm
Meter range 0.04-3800 m3
Totalizer YES
Tank’s Head 6" Flange

WS3 specification sheet

Housing img

2” CONTROL VALVES (SOFTENER)

 

  WS2EI WS2EE WS2CI WS2SD/SP WS2SQ
Type by Time by Meter by Meter by Meter by Meter
Service Flow 115 gpm 115 gpm 115 gpm 115 gpm 115 gpm
Backwash Flow 80 gpm 80 gpm 80 gpm 80 gpm 80 gpm
Drain connection 1.5" FNPT 1.5" FNPT 1.5" FNPT 1.5" FNPT 1.5" FNPT
Brine connection 1" NPT 1" NPT 1" NPT 1" NPT 1" NPT
Distributor pipe 50 mm OD 50 mm OD 50 mm OD 50 mm OD 50 mm OD
Meter flow 1.5–150 gpm 1.5–150 gpm 1.5–150 gpm 1.5–150 gpm 1.5–150 gpm
Meter range 0.02-5700 m3 0.04-5700 m3 0.02-5700 m3 0.04-5700 m3 0.02-5700 m3
Totalizer YES YES YES YES YES
Tank’s Head 4" 4" 4" 4" 4"

 


WS2EI DATA SHEET
WS2SQ DATA SHEET
WS2SD/SP DATA SHEET
WS2EE DATA SHEET
WS2CI DATA SHEET

Housing img

1.5” CONTROL VALVES (SOFTENER)

  V15EEDT V15EEDM
Type by Time by Meter
Service Flow 70 gpm 70 gpm
Backwash Flow 52 gpm 52 gpm
Drain connection 1.25" FNPT 1.25" FNPT
Brine connection ¾" FNPT ¾" FNPT
Distributor pipe 50 mm OD 50 mm OD
Meter flow N/A 2-284 lpm
Meter range N/A 0.02-5700 m3
Totalizer N/A YES
Tank’s Head 4" 4"

Housing img

1.25” CONTROL VALVES (SOFTENER)

  V125TCDT V125EEDM
Type by Time by Meter
Service Flow 34 gpm 34 gpm
Backwash Flow 32 gpm 32 gpm
Drain connection ¾" NPT ¾" NPT
Brine connection ⅜" or ½" OD ⅜" or ½" OD
Distributor pipe 32 mm OD 32 mm OD
Meter flow N/A 0.95-129 lpm
Meter range N/A 0.02-5700 m3
Totalizer N/A YES
Tank’s Head 2.5" 2.5"

Housing img

1” CONTROL VALVES (SOFTENER)

  V1TCDT V1EEDM
Type by Time by Meter
Service Flow 27 gpm 27 gpm
Backwash Flow 27 gpm 27 gpm
Drain connection ¾" NPT ¾" NPT
Brine connection ⅜" or ½" OD ⅜" or ½" OD
Distributor pipe 1.05" OD 1.05" OD
Meter flow N/A 0.95-102 lpm
Meter range N/A 0.02-5700 m3
Totalizer N/A YES
Tank’s Head 2.5" 2.5"

Housing img

3” BACKWASH VALVE (FILTER)

  V3BTZ
Type by Meter
Service Flow 946 lpm
Backwash Flow 833 lpm
Drain connection 3" FNPT
Brine connection 1" NPT
Distributor pipe 90 mm OD
Meter flow 13-1325 lpm
Meter range 0.04-3800 m3
Totalizer YES
Tank’s Head 6" Flange

Housing img

2” BACKWASH VALVES (FILTER)

  V2EEBTZ V2HBMZ
Type by Meter by Meter
Service Flow 115 gpm 125 gpm
Backwash Flow 80 gpm 125 gpm
Drain connection 1.5" FNPT 2" FNPT
Brine connection 1" NPT 1" NPT
Distributor pipe 50 mm OD 63 mm OD
Meter flow 5.7-568 lpm 5.7-473 lpm
Meter range 0.02-5700 m3 0.02-5700 m3
Totalizer N/A YES
Tank’s Head 4" 4"

Housing img

1.5” BACKWASH VALVES (FILTER)

  V15EEBTZ
Type by Meter
Service Flow 70 gpm
Backwash Flow 52 gpm
Drain connection 1.25" FNPT
Brine connection ¾" FNPT
Distributor pipe 50 mm OD
Meter flow 2-284 lpm
Meter range 0.02-5700 m3
Totalizer YES
Tank’s Head 4"

Housing img

1.25” BACKWASH VALVES (FILTER)

  V125TCBTZ V125EEBMZ
Type by Time by Meter
Service Flow 34 gpm 34 gpm
Backwash Flow 32 gpm 32 gpm
Drain connection ¾" NPT ¾" NPT
Brine connection ⅜" or ½" OD ⅜" or ½" OD
Distributor pipe 32 mm OD 32 mm OD
Meter flow N/A 0.95-129 lpm
Meter range N/A 0.02-5700 m3
Totalizer N/A YES
Tank’s Head 2.5" 2.5"

Housing img

1” BACKWASH VALVES (FILTER)

  V1TCBTZ V1EEBMZ
Type by Time by Meter
Service Flow 27 gpm 27 gpm
Backwash Flow 27 gpm 27 gpm
Drain connection ¾" NPT ¾" NPT
Brine connection ⅜" or ½" OD ⅜" or ½" OD
Distributor pipe 1.05" OD 1.05" OD
Meter flow N/A 0.95-102 lpm
Meter range N/A 0.02-5700 m3
Totalizer N/A YES
Tank’s Head 2.5" 2.5"

MANUAL OR AUTOMATIC

Housing img

IN – OUT HEAD

For tanks with 2.5” head opening

Thread: ¾” FNPT

Housing img

AUTOMATIC VALVE FOR WATER SOFTENER

Cycles: Service, Regeneration, Fast Rinse, Brine
Refill
Down-flow regeneration

  V-SES V-SES-M
Type by Time with Meter
By-pass NO YES
Flow 9 gpm 9 gpm
In/Out ¾" FNPT ¾" FNPT
Drain ½" NPT ½" NPT
Brain connection ⅜" ⅜"
Tank’s Head 2.5" 2.5"

Transformer output: 12 VDC, 1.5 A
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)

Housing img

MANUAL VALVE FOR WATER SOFTENER

Cycles: Service, Regeneration, Fast Rinse, Brine
Refill
Down-flow regeneration

  V-SMS V-SMB
Flow 17 gpm 44 gpm
In/Out 1" FNPT 2" FNPT
Drain ½" NPT 1" NPT
Brain connection ⅜" ½"
Riser pipe 1.05" OD 1.5"
Tank’s Head 2.5" 4"

Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)

Housing img

AUTOMATIC VALVE FOR WATER FILTER

Cycles: Service, Backwash, Rinse
Item Part: V-FES
Flow: 17 gpm
In/Out/Drain: 1” FNPT
Riser pipe: 1.05” OD
Tank’s Head: 2.5”
Transformer output: 12 VDC, 1.5 A
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)

Housing img

MANUAL VALVE FOR WATER FILTER

Cycles: Service, Backwash, Rinse

  V-FMS V-FMB
Flow 26 gpm 44 gpm
In/Out 1" FNPT 2" FNPT
Drain 1" FNPT 1.5" FNPT
Tank’s Head 2.5" 4"

Water Pressure: 20 – 85 psi
Water Temperature: 5 – 50 ºC (41-122 ºF)

Housing img

IN – OUT HEAD

For tanks with 2.5” head opening

Thread: ¾” FNPT

Housing img

AUTOMATIC VALVE FOR WATER SOFTENER

Cycles: Service, Regeneration, Fast Rinse, Brine
Refill
Down-flow regeneration

  V-SES V-SES-M
Type by Time with Meter
By-pass NO YES
Flow 9 gpm 9 gpm
In/Out ¾" FNPT ¾" FNPT
Drain ½" NPT ½" NPT
Brain connection ⅜" ⅜"
Tank’s Head 2.5" 2.5"

Transformer output: 12 VDC, 1.5 A
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)

Housing img

MANUAL VALVE FOR WATER SOFTENER

Cycles: Service, Regeneration, Fast Rinse, Brine
Refill
Down-flow regeneration

  V-SMS V-SMB
Flow 17 gpm 44 gpm
In/Out 1" FNPT 2" FNPT
Drain ½" NPT 1" NPT
Brain connection ⅜" ½"
Riser pipe 1.05" OD 1.5"
Tank’s Head 2.5" 4"

Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)

Housing img

AUTOMATIC VALVE FOR WATER FILTER

Cycles: Service, Backwash, Rinse
Item Part: V-FES
Flow: 17 gpm
In/Out/Drain: 1” FNPT
Riser pipe: 1.05” OD
Tank’s Head: 2.5”
Transformer output: 12 VDC, 1.5 A
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)

Housing img

MANUAL VALVE FOR WATER FILTER

Cycles: Service, Backwash, Rinse

  V-FMS V-FMB
Flow 26 gpm 44 gpm
In/Out 1" FNPT 2" FNPT
Drain 1" FNPT 1.5" FNPT
Tank’s Head 2.5" 4"

Water Pressure: 20 – 85 psi
Water Temperature: 5 – 50 ºC (41-122 ºF)