Manual or Automatic valves for filter and Water Softener
Manual or automatic valves for filter and Water Softener Valve
Manual valves for filter and Water Softener are manually operated valves for use on water purification systems. Being resistant, inexpensive and easy to install, they are one of the most used valves in water purification treatment plants. They are also known as manual flow control valves. Applications include: equipment made of zeolite, sand, gravel, garnet, or some and other filter special media, Residential softeners or filters, Iion exchange equipment, Aactivated carbon purifiers, Iindustrial water treatment and pre-treatment systems, Filtration equipment for swimming pools.
Automatic valves are widely used for commercial and residential water filters and softener.
CLACK
WS2HF
- Control Valve Flow Rates: Service 165 gpm (624 lpm) (37 m3/h)
Backwash 175 gpm (662 lpm) (39 m3/h) - Epoxy coated lead free brass valve body
- Fully programmable regeneration cycle times and sequences (maximum 9)
- Network up to 16 valves using Cat5 cable or better
- Methods to initiate regeneration: Meter Delayed, Meter Immediate, Time Clock Delay, Auxiliary Input, Modbus Initiated
- Add up to 2 relay expansion boards to circuit board (sold separately)
- Top-mount or side-mount capabilities for commercial and industrial applications
- Programmable System types: Single, Alternating, Progressive Flow, Series
- Day override feature; 1-28 days or 7 day
- Blue backlight front display shows: Time and Date, Current Flow Rate, Volume Used, Volume Remaining, Days Remaining
- Diagnostics and history viewing
- Modbus RS485 duplex to communicate with building automation systems
- On-Site circuit board software update capability
- Reliable and proven DC drive
- One piece expanding seal spacer stack assembly
General | |
Inlet/Outlet Fitting Connections | 2" Female NPT or BSPT |
Cycles | up to 9 |
Valve Material | Lead free brass |
Regeneration | Downflow |
Operating Pressures | 20 - 125 psi (1.4 - 8.6 bar) |
Operating Temperatures | 40º - 110º F (4º - 43º C) |
Options | Backwash Filter |
FLow rates | |
Service @15 psi drop | 125 gpm (473 lpm) (28.4 m3 /h) |
Backwash @25 psi drop | 125 gpm (473 lpm) (28.4 m3 /h) |
Cv Service | 32.3 |
Cv Backwash | 25.0 |
Tank applications | |
Water Softener | 18" - 63" diameter |
Water Filter | 18" - 48" diameter |
Dimensions & Weight | |
Distributor Pilot | Valve Bodies with 2" Female NPT Inlet & Outlet - 2.375" OD (2" NPS) Valve Bodies with 2" Female BSPT Inlet & Outlet - 63mm OD |
Drain Line | 2" Female NPT/BSPT/2.5" Groove Lock |
Brine Line | 1" Male NPT elbow ¾" x 1" solvent weld elbow Optional Adapters - 1/2" or 5/8" OD Poly Tube Compression |
Mounting Base | 4" - 8 UN, 6" Flange or Side Mount |
Height From Top Of Tank | With 4" - 8 UN QC Base - 11.5" (292mm) With 6" Flange QC Base - 11.6" (294.6mm) |
Weight | 50 lbs (22.7 Kg) |
Cycles of Operation Minutes |
|
Backwash 1st (upflow) | 1 - 95 |
Regenerate Draw/Slow Rinse (downflow) | 1-180 / 1-95 |
Fast Rinse (downflow) | 1-95 |
Regenerant Refill in service with treated water |
0.1 - 99 |
Hold (service) | 1 - 480 |
Electrical Specifications All models excluding WS1.25SD |
US Power Supply | International Power Supply |
Supply Voltage | 120VAC | 240VAC |
Supply Frequency | 60 Hz | 60 Hz |
Output Voltage | 24VDC | 24VDC |
Output Current | 800 mA | 800 mA |
DATA SHEET WS2HF
CL D1400 1" IN/OUT HEAD
BYPASS ASSEMBLY
Can be used with any brand of filter valve, softener valve, or in/out filter (all kind of adapters are available)
For valves 1” (V3006), 1.25” (V3006), 1.5” (V3097), 2” (V3098), 3” (V3099)
Operating pressure: 20-125 psi
Operating temperature: 40-110 °F (4-43 °C)
For installation on cold water supply only
TWIN CONTROL VALVES
In/Out | 1" | 1.25" | 1.5" | 2" |
---|---|---|---|---|
Item Part | VTT1EEDM | Ask | Ask | Ask |
Configuration | 2 valves V1EEDM with V3069 motorized alternator | 2 valves V125EEDM with V3069 motorized alternator | 2 valves V15EEDT with V3071 motorized alternator and V3040-15 meter | 2 valves V2EEDT with V3076 motorized alternator and V3094-15 meter |
3” CONTROL VALVE (SOFTENER)
WS3 | |
---|---|
Type | by Meter |
Service Flow @ 15psi drop |
250 gpm |
Backwash Flow @ 25psi drop |
220 gpm |
Drain connection | 3" FNPT |
Brine connection | 1" NPT |
Distributor pipe | 90 mm OD |
Meter flow | 13-1325 lpm |
Meter range | 0.04-3800 m3 |
Totalizer | YES |
Tank’s Head | 6" Flange |
WS3 specification sheet
2” CONTROL VALVES (SOFTENER)
WS2EI | WS2EE | WS2CI | WS2SD/SP | WS2SQ | |
---|---|---|---|---|---|
Type | by Time | by Meter | by Meter | by Meter | by Meter |
Service Flow | 115 gpm | 115 gpm | 115 gpm | 115 gpm | 115 gpm |
Backwash Flow | 80 gpm | 80 gpm | 80 gpm | 80 gpm | 80 gpm |
Drain connection | 1.5" FNPT | 1.5" FNPT | 1.5" FNPT | 1.5" FNPT | 1.5" FNPT |
Brine connection | 1" NPT | 1" NPT | 1" NPT | 1" NPT | 1" NPT |
Distributor pipe | 50 mm OD | 50 mm OD | 50 mm OD | 50 mm OD | 50 mm OD |
Meter flow | 1.5–150 gpm | 1.5–150 gpm | 1.5–150 gpm | 1.5–150 gpm | 1.5–150 gpm |
Meter range | 0.02-5700 m3 | 0.04-5700 m3 | 0.02-5700 m3 | 0.04-5700 m3 | 0.02-5700 m3 |
Totalizer | YES | YES | YES | YES | YES |
Tank’s Head | 4" | 4" | 4" | 4" | 4" |
WS2EI DATA SHEET
WS2SQ DATA SHEET
WS2SD/SP DATA SHEET
WS2EE DATA SHEET
WS2CI DATA SHEET
1.5” CONTROL VALVES (SOFTENER)
V15EEDT | V15EEDM | |
---|---|---|
Type | by Time | by Meter |
Service Flow | 70 gpm | 70 gpm |
Backwash Flow | 52 gpm | 52 gpm |
Drain connection | 1.25" FNPT | 1.25" FNPT |
Brine connection | ¾" FNPT | ¾" FNPT |
Distributor pipe | 50 mm OD | 50 mm OD |
Meter flow | N/A | 2-284 lpm |
Meter range | N/A | 0.02-5700 m3 |
Totalizer | N/A | YES |
Tank’s Head | 4" | 4" |
1.25” CONTROL VALVES (SOFTENER)
V125TCDT | V125EEDM | |
---|---|---|
Type | by Time | by Meter |
Service Flow | 34 gpm | 34 gpm |
Backwash Flow | 32 gpm | 32 gpm |
Drain connection | ¾" NPT | ¾" NPT |
Brine connection | ⅜" or ½" OD | ⅜" or ½" OD |
Distributor pipe | 32 mm OD | 32 mm OD |
Meter flow | N/A | 0.95-129 lpm |
Meter range | N/A | 0.02-5700 m3 |
Totalizer | N/A | YES |
Tank’s Head | 2.5" | 2.5" |
1” CONTROL VALVES (SOFTENER)
V1TCDT | V1EEDM | |
---|---|---|
Type | by Time | by Meter |
Service Flow | 27 gpm | 27 gpm |
Backwash Flow | 27 gpm | 27 gpm |
Drain connection | ¾" NPT | ¾" NPT |
Brine connection | ⅜" or ½" OD | ⅜" or ½" OD |
Distributor pipe | 1.05" OD | 1.05" OD |
Meter flow | N/A | 0.95-102 lpm |
Meter range | N/A | 0.02-5700 m3 |
Totalizer | N/A | YES |
Tank’s Head | 2.5" | 2.5" |
3” BACKWASH VALVE (FILTER)
V3BTZ | |
---|---|
Type | by Meter |
Service Flow | 946 lpm |
Backwash Flow | 833 lpm |
Drain connection | 3" FNPT |
Brine connection | 1" NPT |
Distributor pipe | 90 mm OD |
Meter flow | 13-1325 lpm |
Meter range | 0.04-3800 m3 |
Totalizer | YES |
Tank’s Head | 6" Flange |
2” BACKWASH VALVES (FILTER)
V2EEBTZ | V2HBMZ | |
---|---|---|
Type | by Meter | by Meter |
Service Flow | 115 gpm | 125 gpm |
Backwash Flow | 80 gpm | 125 gpm |
Drain connection | 1.5" FNPT | 2" FNPT |
Brine connection | 1" NPT | 1" NPT |
Distributor pipe | 50 mm OD | 63 mm OD |
Meter flow | 5.7-568 lpm | 5.7-473 lpm |
Meter range | 0.02-5700 m3 | 0.02-5700 m3 |
Totalizer | N/A | YES |
Tank’s Head | 4" | 4" |
1.5” BACKWASH VALVES (FILTER)
V15EEBTZ | |
---|---|
Type | by Meter |
Service Flow | 70 gpm |
Backwash Flow | 52 gpm |
Drain connection | 1.25" FNPT |
Brine connection | ¾" FNPT |
Distributor pipe | 50 mm OD |
Meter flow | 2-284 lpm |
Meter range | 0.02-5700 m3 |
Totalizer | YES |
Tank’s Head | 4" |
1.25” BACKWASH VALVES (FILTER)
V125TCBTZ | V125EEBMZ | |
---|---|---|
Type | by Time | by Meter |
Service Flow | 34 gpm | 34 gpm |
Backwash Flow | 32 gpm | 32 gpm |
Drain connection | ¾" NPT | ¾" NPT |
Brine connection | ⅜" or ½" OD | ⅜" or ½" OD |
Distributor pipe | 32 mm OD | 32 mm OD |
Meter flow | N/A | 0.95-129 lpm |
Meter range | N/A | 0.02-5700 m3 |
Totalizer | N/A | YES |
Tank’s Head | 2.5" | 2.5" |
1” BACKWASH VALVES (FILTER)
V1TCBTZ | V1EEBMZ | |
---|---|---|
Type | by Time | by Meter |
Service Flow | 27 gpm | 27 gpm |
Backwash Flow | 27 gpm | 27 gpm |
Drain connection | ¾" NPT | ¾" NPT |
Brine connection | ⅜" or ½" OD | ⅜" or ½" OD |
Distributor pipe | 1.05" OD | 1.05" OD |
Meter flow | N/A | 0.95-102 lpm |
Meter range | N/A | 0.02-5700 m3 |
Totalizer | N/A | YES |
Tank’s Head | 2.5" | 2.5" |
MANUAL OR AUTOMATIC
IN – OUT HEAD
For tanks with 2.5” head opening
Thread: ¾” FNPT
AUTOMATIC VALVE FOR WATER SOFTENER
Cycles: Service, Regeneration, Fast Rinse, Brine
Refill
Down-flow regeneration
V-SES | V-SES-M | |
---|---|---|
Type | by Time | with Meter |
By-pass | NO | YES |
Flow | 9 gpm | 9 gpm |
In/Out | ¾" FNPT | ¾" FNPT |
Drain | ½" NPT | ½" NPT |
Brain connection | ⅜" | ⅜" |
Tank’s Head | 2.5" | 2.5" |
Transformer output: 12 VDC, 1.5 A
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)
MANUAL VALVE FOR WATER SOFTENER
Cycles: Service, Regeneration, Fast Rinse, Brine
Refill
Down-flow regeneration
V-SMS | V-SMB | |
---|---|---|
Flow | 17 gpm | 44 gpm |
In/Out | 1" FNPT | 2" FNPT |
Drain | ½" NPT | 1" NPT |
Brain connection | ⅜" | ½" |
Riser pipe | 1.05" OD | 1.5" |
Tank’s Head | 2.5" | 4" |
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)
AUTOMATIC VALVE FOR WATER FILTER
Cycles: Service, Backwash, Rinse
Item Part: V-FES
Flow: 17 gpm
In/Out/Drain: 1” FNPT
Riser pipe: 1.05” OD
Tank’s Head: 2.5”
Transformer output: 12 VDC, 1.5 A
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)
MANUAL VALVE FOR WATER FILTER
Cycles: Service, Backwash, Rinse
V-FMS | V-FMB | |
---|---|---|
Flow | 26 gpm | 44 gpm |
In/Out | 1" FNPT | 2" FNPT |
Drain | 1" FNPT | 1.5" FNPT |
Tank’s Head | 2.5" | 4" |
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 50 ºC (41-122 ºF)
IN – OUT HEAD
For tanks with 2.5” head opening
Thread: ¾” FNPT
AUTOMATIC VALVE FOR WATER SOFTENER
Cycles: Service, Regeneration, Fast Rinse, Brine
Refill
Down-flow regeneration
V-SES | V-SES-M | |
---|---|---|
Type | by Time | with Meter |
By-pass | NO | YES |
Flow | 9 gpm | 9 gpm |
In/Out | ¾" FNPT | ¾" FNPT |
Drain | ½" NPT | ½" NPT |
Brain connection | ⅜" | ⅜" |
Tank’s Head | 2.5" | 2.5" |
Transformer output: 12 VDC, 1.5 A
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)
MANUAL VALVE FOR WATER SOFTENER
Cycles: Service, Regeneration, Fast Rinse, Brine
Refill
Down-flow regeneration
V-SMS | V-SMB | |
---|---|---|
Flow | 17 gpm | 44 gpm |
In/Out | 1" FNPT | 2" FNPT |
Drain | ½" NPT | 1" NPT |
Brain connection | ⅜" | ½" |
Riser pipe | 1.05" OD | 1.5" |
Tank’s Head | 2.5" | 4" |
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)
AUTOMATIC VALVE FOR WATER FILTER
Cycles: Service, Backwash, Rinse
Item Part: V-FES
Flow: 17 gpm
In/Out/Drain: 1” FNPT
Riser pipe: 1.05” OD
Tank’s Head: 2.5”
Transformer output: 12 VDC, 1.5 A
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 45 ºC (41-113 ºF)
MANUAL VALVE FOR WATER FILTER
Cycles: Service, Backwash, Rinse
V-FMS | V-FMB | |
---|---|---|
Flow | 26 gpm | 44 gpm |
In/Out | 1" FNPT | 2" FNPT |
Drain | 1" FNPT | 1.5" FNPT |
Tank’s Head | 2.5" | 4" |
Water Pressure: 20 – 85 psi
Water Temperature: 5 – 50 ºC (41-122 ºF)